At the BSPool technical service we frequently receive queries from users and installers concerned about reddish stains appearing on ladders, lights or pumps after starting up a salt chlorinator. The intuitive diagnosis usually points to salt as the direct culprit; however, in our field inspections we find that in more than 95% of cases the damage is due to stray currents that are not earthed or to a prolonged chemical imbalance that attacks the metal alloys.

1. Theoretical salinity vs. galvanic corrosion

There is a belief that salt water attacks metal by its chemical nature. To assess the real risk, it helps to compare the figures: seawater has concentrations of around 35,000 ppm (35 g/l), whereas a residential salt electrolysis system works at only 3,000 to 5,000 ppm (3 to 5 g/l).

At these levels, the water does not by itself degrade resistant alloys such as marine-grade stainless steel. However, adding salt noticeably increases the water’s electrical conductivity, turning it into an active electrolyte. If two different metals are in contact with the water and there is no escape path for residual electrical micro-currents, galvanic corrosion is triggered: the less noble metal continuously gives up electrons and corrodes quickly.

2. Critical factors that cause corrosion in the pool

Salt acts only as a conductor that exposes installation errors or water imbalances. These are the three direct causes of corrosion in metal components:

  • Acidic pH out of range (< 7.0): Water with an acidic pH dissolves the passive chromium oxide layer that protects stainless steel, leaving it vulnerable to immediate corrosion, whether or not there is salt in the pool.
  • Sustained excess free chlorine (> 3-4 ppm): Uncontrolled disinfectant production creates a high oxidation potential that attacks elastomers and metal fasteners, accelerating pitting corrosion (pitting).
  • Unsuitable alloys in fittings (AISI 304 vs. AISI 316L): Standard AISI 304 steel lacks the molybdenum content needed to withstand chlorinated, humid environments; in pools with electrolysis it is essential to install AISI 316L components.

3. Technical neutralisation protocol: automation and earthing

To eliminate galvanic degradation and keep metal elements protected in the long term, the installation must combine physical equipotential bonding with continuous analytical control:

  • Water earthing (Pool Terre Kit): Mandatory connection in ranges such as N-BSsalt or Touch Evo. It diverts to earth the stray currents generated by water friction and the chlorinator’s electronics, preventing the ladder or pump shaft from acting as a sacrificial anode.
  • Continuous pH and redox regulation: Units such as the Evo range dose pH reducer proportionally and adjust electrolysis output according to actual demand, avoiding corrosive free chlorine peaks.
  • Diagnostics and control with BSLINK: Lets you monitor pH and salinity values from your smartphone, alerting you instantly if parameters fall to levels that are aggressive for pool components.