OFFICIAL TECHNICAL SUPPORT
Specialist support and documentation in a single click
MANUALS AND INSTALLATION Manuals and videos
Every unit, with all its documentation. Every unit, with its manual and video.
Step-by-step guides, assembly manuals, exploded views and video content.
TOUCH EVO
TOUCH EVO LINK
TOUCH EVO+
TOUCH LS
TOUCH LS LINK
TOUCH MG
TOUCH MG LINK
QUICKSALT-E
BSLINK also in public pools
BSLINK also in private pools
PRO50/70/100/150
PRO200
PRO250
PRO400/500/600/750/1000
TOUCH PRO 50/70/100/150
EVOPH-P-2
EVORX-P-2
KIT PRO/2
P-PHRX
P-PHCL
PC16X-ECO
PC20X-ECO
PC40X-ECO
PC741
PC SMART+
INSTALLATION AND START-UP
From installation to start-up, step by step.
Official assembly protocols aligned with the 2026/2027 catalogue to ensure maximum durability and performance of your equipment.
PHASE 01
Installation protocol
4 steps
-
Equipment switched off and disconnected from power
Disconnect the main power supply before handling the control panel.
-
Installing the control unit
Mount on a ventilated wall, protected from direct sunlight and with an earth connection.
-
Installing the cell
Vertical position on the return line (in bypass), always after the filtration system.
-
Electrical connection of the cell
Connect the cell cables to the control panel according to your model's wiring diagram.
Depending on model
THE UNIT IS NOW INSTALLED
PHASE 02
Start-up protocol
6 steps
FREQUENTLY ASKED QUESTIONS
Clear answers for the daily care of your water.
We answer the most common questions received by our technical team. If you can't find the answer, use the search bar at the top to look up your model's manual.
Why is the water greenish or brown, and how do I fix it?
Greenish water: indicates algae caused by low disinfection levels, a pH imbalance or insufficient filtration.
Steps to restore water clarity:
- Adjust the pH: check it and keep it within the optimal range (between 7.2 and 7.4).
- Shock treatment: activate the superchlorination function on your salt unit or carry out a shock chlorination, keeping filtration running for 24-48 h.
- Cleaning and clarifying: brush the walls and floor, apply flocculant and backwash the filter at the end of the process.
Why is the water brownish, and how do I fix it?
Brownish or brown water: usually caused by oxidation of metals (iron or copper) present in the fill water.
Steps to restore water clarity:
- Adjust the pH: check it and keep it within the optimal range (between 7.2 and 7.4).
- Avoid initial shock chlorination: if the source is well-water iron, chlorine will oxidise it further and make it darker.
- If it is caused by metals (well water): add a metal sequestrant directly to the water.
Why does the water smell strongly of chlorine or sting the eyes, and how do I fix it?
Contrary to popular belief, a strong chemical smell and eye irritation are not caused by too much chlorine, but by the presence of chloramines (combined chlorine). These form when the disinfectant combines with organic matter and the water is not properly renewed or disinfected.
Steps to eliminate chloramines:
- Adjust the pH: keep it strictly between 7.2 and 7.4. An unbalanced pH drastically reduces treatment effectiveness.
- Superchlorination / chloramine destruction: activate superchlorination mode on your BS Pool salt unit (or apply a shock treatment) to break down the chloramines and restore water purity.
- Renewal and filtration: keep filtration running continuously for 24 h and ensure good pool recirculation.
Is it normal for a disinfected pool to lose chlorine after filtering?
Yes. Sunlight, high water temperature and bathers constantly consume free chlorine, even if the unit has been running.
BS Pool recommendations:
- Check the pH range.
- Align filtration hours and salt output with the hours of strongest sunlight.
- Automate readings with ORP/redox sensors to respond to demand in real time.
How often should I chlorinate the pool if it is hardly used?
Disinfection should be daily and continuous, but at a lower intensity. Salt systems let you set output to the minimum needed to prevent algae or bacteria growth.
Key guidelines:
- Set the chlorinator output to 10%-20% and reduce filtration hours.
- Keep the pH between 7.2 and 7.4.
- Monitor parameters remotely with the BSLINK platform.
What causes limescale and how do I remove it?
It appears due to alkaline (high) pH or very hard water. It causes white stains in the pool and clogs the salt chlorinator's plates.
Quick fix:
- Check and lower the pH to a range of 7.2 to 7.4.
- Make sure the unit's polarity reversal function is active for cell self-cleaning.
- Use a maintenance anti-scale product if your mains water is very hard.
What causes algae in the water?
Algae appear due to a lack of active chlorine in the pool, encouraged by high pH, insufficient filtration or high water temperature.
Quick fix:
- Adjust the pH to 7.2 – 7.4.
- Run a superchlorination with the salt unit (Boost mode) and filter non-stop for 24 to 48 h.
- Brush the pool, apply flocculant and clean the filter afterwards.
What happens when the pool's alkalinity is very high?
It locks the pH at high values, clouds the water and increases limescale build-up in the equipment, as well as reducing chlorine efficiency.
Steps to fix it:
- Apply pH reducer in measured doses to lower alkalinity to the 80 – 120 ppm range.
- Filter continuously to evenly distribute the treatment.
- Automate readings with the salt chlorinator kits to protect the salt cell.
How does low alkalinity affect the pool?
Low alkalinity causes a series of problems both in the water chemistry and in the pool's structure and equipment: unstable pH, corrosive water, irritation for bathers and green or cloudy water.
Steps to fix it:
- Use alkalinity increaser in the proportion recommended by the manufacturer.
- Keep filtration running for 24 h.
- Measure and adjust the pH to 7.2 – 7.4.
TROUBLESHOOTING
Your unit is warning you: learn how to read its messages.
Guide to display alerts with the step-by-step checks you can carry out and the official recommendation for requesting technical support.
Tap the alert you see on the display.
-
Low salt
The salt concentration is below the minimum working level and output drops.
-
Check the actual salinity: verify the level with an independent test (recommended value: 4 g/l in private pools and 5 g/l in public pools).
-
Inspect the cell: check for limescale build-up, as a dirty or scaled cell can distort the display reading.
-
Check the lifespan: check the operating hours in the menu; if it has exceeded ¾ of its lifespan, the reading may indicate electrode wear.
-
Add salt and mix: if salinity is low, add the required amount for your model with filtration running and wait for it to dissolve before measuring again.
If the alert does not disappear, request a repair or contact your technical service.
-
-
Too much salt
There is too much salt in the water. It does not affect operation or the cell's lifespan.
-
Check that a cell with a higher output than the one specified for the unit has not been installed.
-
It is not important unless it reaches the short-circuit alarm, in which case the only solution is to drain some water from the pool and refill with unsalted water.
If the alert does not disappear, request a repair or contact your technical service.
-
-
Cleaning
The unit has switched to cleaning mode to optimise the cell.
No action is needed. When the cycle ends, it will return to its normal set operation.
-
Temperature
The unit is overheating internally. When the temperature drops, it will automatically return to normal operation. This alarm stops the unit when the ambient temperature is above 40 °C.
-
Move the unit to a place where the temperature does not exceed 40 °C, add forced ventilation or improve ventilation, and keep it out of direct sunlight.
-
Check that the heat sink fins are not blocked and that the unit is in a vertical position.
-
Position the unit so that air can circulate for proper cooling.
If the alert does not disappear, request a repair or contact your technical service.
-
-
Temperature flashing
The water temperature is below 15 °C.
If you wish, you can stop the unit and use a winterising method so the cell does not wear out.
-
No flow
This may be because there is no water circulating through the cell housing or there is excess gas in the electrolytic cell, for example because the pump has stopped. Check the installation.
-
Check that the connection between the water sensor and the power board (white cable) is correct, as well as the condition of the cable and its terminals.
-
Make sure water is flowing normally through the housing and that no air bubbles form at the top. Bleed if necessary.
-
The water sensor must remain submerged at all times. Also make sure the salt level is correct and that the salt has dissolved.
-
Check that the cell and water sensor are free from scale. Clean if necessary.
-
Test: the water sensor can be "bridged" at connections 5-6 as a test; if the alert disappears, review the options above. Important: this bridge should only be made to rule out a problem with the water sensor. DO NOT LEAVE IT LIKE THIS.
If the alert does not disappear, request a repair or contact your technical service.
-
-
Open circuit
Check the connection of the cell cables to the unit.
-
Check that the salt concentration is sufficient and that it is dissolved in the water.
-
Check that water is circulating through the cell housing.
-
Remove the cell and check its condition: if there is limescale build-up, clean it.
-
If it is clean, check its wear: if the catalytic coating has worn away completely, this alarm may appear. We recommend testing with a replacement cell.
If the alert does not disappear, request a repair or contact your technical service.
-
-
Short circuit
Check that there are no foreign objects in the cell housing.
-
Check the salt concentration in the water: a very high salt level can trigger a short-circuit alarm.
-
Check the wiring: rule out a poor connection that would cause the cable itself to overheat.
-
Check that the salt concentration does not exceed 9 g/l.
If the alert does not disappear, request a repair or contact your technical service.
-
-
CL error
Indicates a malfunction in the redox or free chlorine probe. When the reading stays at one value for a certain period (usually 0 or a value that does not change), production stops and this error appears.
-
Check that the probe is connected to the REDOX input.
-
Make sure the wiring from the BNC connector to the power board is correct.
-
Check the probe with the supplied 468 mV buffer solution; if the value is correct, analyse this value in the pool water.
If the alert does not disappear, request a repair or contact your technical service.
-
-
pH error
Indicates that the pump has been running non-stop for 2 h and stops it, although not the chlorinator.
-
Check the condition of the probe: clean or replace if necessary.
-
Use the buffer solutions to calibrate the probes and make sure the readings are correct.
-
Replace the probe if calibration fails.
If the alert does not disappear, request a repair or contact your technical service.
-
Request a repair for your unit
Download the official repair request (RMA), find your assigned centre and send the unit, properly protected, for inspection by the SAT.
- Download and complete the RMA form
- Find your Official Technical Service (SAT)
- Attach the document and include the unit in the package
OFFICIAL SERVICE NETWORK
Find your nearest official technical support centre
Direct factory support throughout Spain. Enter your location to find the Official Technical Service (SAT) or authorised distributor assigned to your area.
Tell us where you are and we will tell you who will assist you.
21 centres in the network
-
Technical service
Barcelona · Girona
-
Technical service
Málaga
-
Technical service
Galicia
-
Technical service
Pontevedra
-
Technical service
Murcia
-
Technical service
Granada · Jaén
-
Technical service
Tarragona
-
Technical service
Alicante
-
Technical service
Cádiz
-
Technical service
Almería
-
Technical service
Madrid
-
Technical service
Huelva
-
Technical service
Mallorca · Ibiza
-
Technical service
Sevilla
-
Technical service
Cáceres · Badajoz
-
Technical service
Elche · Alicante
-
Technical service
Tenerife
-
Technical service
Menorca
-
Technical service
Las Palmas
-
Technical service
Valencia
-
Factory · Central service
Sant Fruitós de Bages · 08272 Barcelona
We found no centres for that search.